EDI's wide range of vehicle detection products help technicians save valuable time and maximize profits by quickly installing, accurately trouble-shooting, and reliably maintaining access control systems with easy to use hi-tech vehicle detectors that provide built-in set-up tools, a frequency meter, a signal “CALL” strength meter, and non-volatile memory to maintain diagnostic history, all of which are invaluable and always available - Because they're built-in!
|
|
|
|
LMA-1500 “DEFLECTOMETER” Series - Plug In Type
Benefits: Built-in set-up tools, frequency meter, signal strength meter and trouble-shooting indicators.
Channels / Outputs: Single Channel with Dual Solid State Outputs
Type / Connector: Plug-in / PCB mount type with 10-pin Female Molex Connector - Rear mount
Size: 2.30” (5.84cm.) high x 2.75” (6.98 cm.) wide x 0.80” (2.03 cm.) thick
Model Number Description
LMA-1500 Standard Model: Operates on 12 VDC, 24 VDC, & 24 VAC - Infinite Presence, Limited Presence, Pulse-on-entry, & Pulse-on-exit options - DIP switch selectable
Fail Safe or Fail Secure Configuration.
LMA-1500-LP Low Power Model: Power consumption in the NO DETECT state is less than 8 milliamps.
|
|
|
|
|
|
|
|
|
|
LMA-1400 “DEFLECTOMETER” Series - Universal Mount Type
Benefits: Built-in set-up tools, frequency meter, signal strength meter and trouble-shooting indicators.
Channels / Outputs: Single Channel with Dual Relay Outputs. Solid State Outputs available upon request.
Type / Connector: Plug-in / PCB mount type with 10-pin Female or Male Molex type or 10-pin Block Terminal type.
Size: 4.14” (10.52 cm.) high x 2.71” (6.88 cm.) wide x 0.75” (1.91 cm.) thick.
Model Number Description
LMA-1400-F Operates on 10 to 30 VDC and 24 VAC - Female Molex Connector - Infinite Presence, Limited Presence, Pulse-on-entry, & Pulse-on-exit options - DIP switch selectable - Fail Safe or Fail Secure Configuration.
LMA-1400-M Operates on 10 to 30 VDC and 24 VAC - Male Molex Connector - Infinite Presence, Limited Presence, Pulse-on-entry, & Pulse-on-exit options - DIP switch selectable - Fail Safe or Fail Secure Configuration.
LMA-1400-B Operates on 10 to 30 VDC and 24 VAC - Block Terminal Connector - Infinite Presence, Limited Presence, Pulse-on-entry, & Pulse-on-exit options - DIP switch selectable - Fail Safe or Fail Secure Configuration.
|
|
|
|
|
|
|
|
|
|
LMA-1250 “DEFLECTOMETER” Series - Enclosure/Box Type
Benefits: Built-in set-up tools, frequency meter, signal strength meter and trouble-shooting indicators.
Channels / Outputs: Single Channel with Dual Relay Outputs
Type / Connector : Box “Enclosure” type with 11-pin Male “Amphenol” Connector - Rear mount
Size: 2.875” (7.30cm.) long x 1.375” (3.49 cm.) wide x 3.063” (7.78 cm.) tall
Model Number Description
LMA-1250-LV Operates on 12 VDC, 24 VDC, & 24 VAC - Infinite Presence, Limited Presence, Pulse-on-entry, & Pulse-on-exit options - Fail Safe Configuration.
LMA-1250S-LV Operates 12 VDC, 24 VDC, & 24 VAC - Infinite Presence, Limited Presence, Pulse-on-entry, & Pulse-on-exit options - Fail Secure Configuration.
LMA-1250-HV Operates on 120 & 240 VAC - Infinite Presence, Limited Presence, Pulse-on-entry, & Pulse-on-exit options - Fail Safe Configuration.
LMA-1250S-HV Operates on 120 & 240 VAC - Infinite Presence, Limited Presence, Pulse-on-entry, & Pulse-on-exit options - Fail Secure Configuration..
|
|
|
|
|
|
|
|
|
|
LMA-1150 “DEFLECTOMETER” Series - Enclosure/Box Type
Benefits: Built-in set-up tools, frequency meter, signal strength meter and trouble-shooting indicators.
Channels / Outputs: Single Channel with Single Relay Output
Type / Connector : Box “Enclosure” type with 11-pin Male “Amphenol” Connector - Rear mount
Size: 2.875” (7.30cm.) long x 1.375” (3.49 cm.) wide x 3.063” (7.78 cm.) tall
Model Number Description
LMA-1150-LV Operates on 12 VDC, 24 VDC, & 24 VAC - Infinite Presence, Limited Presence, Pulse-on-entry, & Pulse-on-exit options - Fail Safe Configuration.
LMA-1150S-LV Operates 12 VDC, 24 VDC, & 24 VAC - Infinite Presence, Limited Presence, Pulse-on-entry, & Pulse-on-exit options - Fail Secure Configuration.
LMA-1150-HV Operates on 120 & 240 VAC - Infinite Presence, Limited Presence, Pulse-on-entry, & Pulse-on-exit options - Fail Safe Configuration.
LMA-1150S-HV Operates on 120 & 240 VAC - Infinite Presence, Limited Presence, Pulse-on-entry, & Pulse-on-exit options - Fail Secure Configuration.
|
|
|
|
|
|
|
|
|
|
LMA-100 Series - Enclosure/Box Type
Channels / Outputs: Single Channel with Single Relay Output
Type / Connector : Box “Enclosure” type with 11-pin Male “Amphenol” Connector - Rear mount
Size: 2.875” (7.30cm.) long x 1.375” (3.49 cm.) wide x 3.063” (7.78 cm.) tall
Model Number Description
LMA-100-LV Operates on 12 VDC, 24 VDC, & 24 VAC - Infinite Presence, Limited Presence, Pulse-on-entry, & Pulse-on-exit options - Fail Safe Configuration.
LMA-100S-LV Operates 12 VDC, 24 VDC, & 24 VAC - Infinite Presence, Limited Presence, Pulse-on-entry, & Pulse-on-exit options - Fail Secure Configuration.
LMA-100-HV Operates on 120 & 240 VAC - Infinite Presence, Limited Presence, Pulse-on-entry, & Pulse-on-exit options - Fail Safe Configuration.
LMA-100S-HV Operates on 120 & 240 VAC - Infinite Presence, Limited Presence, Pulse-on-entry, & Pulse-on-exit options - Fail Secure Configuration.
|
|
|
|
|
|
|
|
|
|
LMA-200 Series - Enclosure/Box Type
Channels / Outputs: Single Channel with Dual Relay Outputs
Type / Connector : Box “Enclosure” type with 11-pin Male “Amphenol” Connector - Rear mount
Size: 2.875” (7.30cm.) long x 1.375” (3.49 cm.) wide x 3.063” (7.78 cm.) tall
Model Number Description
LMA-200-LV Operates on 12 VDC, 24 VDC, & 24 VAC - Infinite Presence, Limited Presence, Pulse-on-entry, & Pulse-on-exit options - Fail Safe Configuration.
LMA-200S-LV Operates 12 VDC, 24 VDC, & 24 VAC - Infinite Presence, Limited Presence, Pulse-on-entry, & Pulse-on-exit options - Fail Secure Configuration.
LMA-200-HV Operates on 120 & 240 VAC - Infinite Presence, Limited Presence, Pulse-on-entry, & Pulse-on-exit options - Fail Safe Configuration.
LMA-200S-HV Operates on 120 & 240 VAC - Infinite Presence, Limited Presence, Pulse-on-entry, & Pulse-on-exit options - Fail Secure Configuration.
|
|
|
|
|
|
|
|
|
|
LMH4-11 Heavy Duty Connecting Harness
Model Number Description
LMH4-11 11-pin female “Amphenol” connector - 4 foot in length with unterminated color coded wires - Loop wires are twisted - Compatible with all 11-pin box type vehicle detectors.
|
|
|